- Helukabel Việt Nam
- MICRO-EPSILON
- FrigorTec
- ZELTWANGER VIỆT NAM
- Clyde Việt Nam
- Electro-Chemical Devices (ECD)
- FER-strumenti Việt Nam
- Filternox Việt Nam
- D-Hydro
- FER Strumenti VIỆT NAM
- NUOVA FIMA VIETNAM
- Dover Flexo Electronics
- FTI Flow Technology
- OHKURA VIETNAM
- ASHCROFT VIỆT NAM
- DWYER VIỆT NAM
- BROOKS INSTRUMENT
- VEGA VIETNAM
- SCHENCK PROCESS VIETNAM
- FIREYE VIETNAM
- MOOG VIETNAM
- K0GANEI VIETNAM
- QUALITEST VIETNAM
- TECLOCK VIETNAM
- TEKTROL VIETNAM
- CELLAPORT PT VIETNAM
- WISE VIETNAM
- AT2E VIETNAM
- TEMA VIETNAM
- Taihei Boeki VIỆT NAM
- CEIA VIETNAM
- KNICK VIETNAM
- PRESSURE TECH VIỆT NAM
- ME-Meßsysteme VIỆT NAM
- TDK LAMBDA
- KLOEPPER-THERM VIỆT NAM
- BIRCHER VIETNAM
- IBA VIETNAM
- SORINC VIET NAM
- MONTECH VIET NAM
- BURKERT VIETNAM
- NIRECO VIETNAM
- CEMB VIETNAM
- MARK-10 VIETNAM
- GASTRON VIETNAM
- RED LION VIETNAM
- MATSUSHIMA VIETNAM
- TAKENAKA VIETNAM
- PORA VIETNAM
- GEMU VIETNAM
- BECKHOFF VIETNAM
Oxygen analyzers SYRE - FER-strumenti
-
CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT
Địa chỉ: Số 1, Đường số 27, phường Hiệp Bình Chánh, Quận Thủ Đức, Tp.HCM
Tell / zalo: 0977 204 306 / 0914 599 052
Email: sale18@tmpvietnam.com
Skype: duyvu181387@gmail.com
-
-
- Thông Tin Sản Phẩm
- Đánh Giá
Oxygen analyzers SYRE - FER-strumenti
Technical Specifications
• Measuring field: 0,0001 ÷ 25% di O2 in volume
• Precision: ±0.5% of the theoretical value or 0.05% O2 (le plus élevé des deux)
• Stability: within 1%
• Response time (90%): zirconia cell < 1", the whole system < 15"
• Storage temperature: -40°C/+80°C
• Working temperature: probe 600° ÷ 1600° C for the temperature of the process; < 150° C for the head of the probe; transmitter: -25° ÷ +65° C
• Analog output: passive 4-20 mA conform to Namur NE 43 recommendation. Settable O2 range
• In case of fault the analogical outputs are forced to 3.75 mA
• Interfaces: point-to-point HART protocol rev.6.0
• Dumper: time constant adjustable between 0 and 900 sec.
• Power supply (on 4-20 signal cables): 24 Vdc max 900ohm.
• EMC: according to EN61000-6-1:2007, EN61000-6-2:2019, EN61000-6-3:2007, EN61000-6-4:2007
• Compliance with the Atex directive relating to equipment: II 2G IIC T4 Gb, II 2D IIIC T135°C Db
• EAC Certificate in compliance with Technical Regulation of Custom Union TR CU 012/2011 " On safety of equipment intended for use in explosive atmospheres"; TR-CU-004 and TR-CU-020
• Pattern Approval Certificate (PAC) for Russian custom union
• Transmitter enclosure certification: Ex d II C T4 -T6, Ex tDA21 IP66 T85°C T135°C
• Relative humidity < 90% non condensating
• Probe Dimension: immersion length: 900, 650, 500, 310 mm; diameter: 28 mm; with extension tubes 1500mm of immersion length can be reached; Transmitter: 138 h.93 mm.; flow-meters box: 230x300 h. 170 mm.
• Instrumentation air pressure: 2-12 bar
• Fittings for tubing: mm. 6x4 or ¼” NPT-F
• Inlets for electrical connections: M20 x 1.5