danh mục sản phẩm
- Helukabel Việt Nam
- MICRO-EPSILON
- FrigorTec
- ZELTWANGER VIỆT NAM
- Clyde Việt Nam
- Electro-Chemical Devices (ECD)
- FER-strumenti Việt Nam
- Filternox Việt Nam
- D-Hydro
- FER Strumenti VIỆT NAM
- NUOVA FIMA VIETNAM
- Dover Flexo Electronics
- FTI Flow Technology
- OHKURA VIETNAM
- ASHCROFT VIỆT NAM
- DWYER VIỆT NAM
- BROOKS INSTRUMENT
- VEGA VIETNAM
- SCHENCK PROCESS VIETNAM
- FIREYE VIETNAM
- MOOG VIETNAM
- K0GANEI VIETNAM
- QUALITEST VIETNAM
- TECLOCK VIETNAM
- TEKTROL VIETNAM
- CELLAPORT PT VIETNAM
- WISE VIETNAM
- AT2E VIETNAM
- TEMA VIETNAM
- Taihei Boeki VIỆT NAM
- CEIA VIETNAM
- KNICK VIETNAM
- PRESSURE TECH VIỆT NAM
- ME-Meßsysteme VIỆT NAM
- TDK LAMBDA
- KLOEPPER-THERM VIỆT NAM
- BIRCHER VIETNAM
- IBA VIETNAM
- SORINC VIET NAM
- MONTECH VIET NAM
- BURKERT VIETNAM
- NIRECO VIETNAM
- CEMB VIETNAM
- MARK-10 VIETNAM
- GASTRON VIETNAM
- RED LION VIETNAM
- MATSUSHIMA VIETNAM
- TAKENAKA VIETNAM
- PORA VIETNAM
- GEMU VIETNAM
- BECKHOFF VIETNAM
hỗ trợ tư vấn
THỐNG KÊ TRUY CẬP
Đang online: 3
Truy cập ngày: 154
Truy cập tuần: 772
Truy cập tháng: 2818
Tổng truy cập: 302969
liên kết website
Sản phẩm
Oxygen analyzers Mod. OXYL - FER-strumenti
-
CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT
Địa chỉ: Số 1, Đường số 27, phường Hiệp Bình Chánh, Quận Thủ Đức, Tp.HCM
Tell / zalo: 0977 204 306 / 0914 599 052
Email: sale18@tmpvietnam.com
Skype: duyvu181387@gmail.com
-
-
- Thông Tin Sản Phẩm
- Đánh Giá
Oxygen analyzers Mod. OXYL - FER-strumenti
- Excellent stability
- High response time
- No calibration needed
- Absolute safety
- Direct process insertion
- Approved for zone 1G/D
- Attractive price
Technical Specifications:
• Measuring range: 0,0001 ÷ 25% O2 in volume
• Precision: ±0.5% of the theoretical value or 0.1% O2 (whichever is the greater)
• Stability: within 1%
• Response time (90%): zirconia cell < 1", the whole system < 15"
• Storage temperature: probe -40°C/+80°C
• Working temperature:
o Probe: room temperature ÷ 600° C for the part in the process
o Head of the probe < 135° C
o Converter and barrier: -20° ÷ +50° C
• Analog output: 4÷20 mA 500 ohm or 0÷10 V 10 mA linear on one of the following fields: 0÷1999 ppm;
0÷5%; 0÷10%; 0÷25%
• Interfaces: RTU Mod-bus protocols on RS485, HART protocol optional
• Alarms: (potential free contacts) high and low O2, fault (fail safe) service and calibration in progress. For all
contacts 24 V, 1 A max
• In case of fault the analogical outputs are forced to 2 mA or 0 V
• Dumper: time constant adjustable between 0 and 900 sec
• Power supply: 115V and 230 V ±10%, 50/60 Hz 200 VA max
• EMC: according to EN 50081 and EN 50082
• Electric safety: according to EN 61010 – 1
• Protection: Ex II 2G c IIC T4 and Ex II 2D IP66 T 135 °C
• Conformity certificate according to ATEX and CEI EN 60079-0,-11,14/ CEI EN 13463-1,-5 / CEI EN
61241-0, -1, -14, 17
• Relative humidity < 90% non condensing
• Probe dimensions: immersion length= 350, 500, 1000 mm; diameter: 60.5 mm
• Transmitter dimensions mm. 305x330 h.200.
• flow-meters box: mm. 230x300 h. 170
• Instrumentation air pressure: 2-12 bar
• Compression fittings for tubing: mm. 6x4 or ¼” NPT-F
• Electrical connections: mm. 20x1.5 or ½”” NPT-F
• Measuring range: 0,0001 ÷ 25% O2 in volume
• Precision: ±0.5% of the theoretical value or 0.1% O2 (whichever is the greater)
• Stability: within 1%
• Response time (90%): zirconia cell < 1", the whole system < 15"
• Storage temperature: probe -40°C/+80°C
• Working temperature:
o Probe: room temperature ÷ 600° C for the part in the process
o Head of the probe < 135° C
o Converter and barrier: -20° ÷ +50° C
• Analog output: 4÷20 mA 500 ohm or 0÷10 V 10 mA linear on one of the following fields: 0÷1999 ppm;
0÷5%; 0÷10%; 0÷25%
• Interfaces: RTU Mod-bus protocols on RS485, HART protocol optional
• Alarms: (potential free contacts) high and low O2, fault (fail safe) service and calibration in progress. For all
contacts 24 V, 1 A max
• In case of fault the analogical outputs are forced to 2 mA or 0 V
• Dumper: time constant adjustable between 0 and 900 sec
• Power supply: 115V and 230 V ±10%, 50/60 Hz 200 VA max
• EMC: according to EN 50081 and EN 50082
• Electric safety: according to EN 61010 – 1
• Protection: Ex II 2G c IIC T4 and Ex II 2D IP66 T 135 °C
• Conformity certificate according to ATEX and CEI EN 60079-0,-11,14/ CEI EN 13463-1,-5 / CEI EN
61241-0, -1, -14, 17
• Relative humidity < 90% non condensing
• Probe dimensions: immersion length= 350, 500, 1000 mm; diameter: 60.5 mm
• Transmitter dimensions mm. 305x330 h.200.
• flow-meters box: mm. 230x300 h. 170
• Instrumentation air pressure: 2-12 bar
• Compression fittings for tubing: mm. 6x4 or ¼” NPT-F
• Electrical connections: mm. 20x1.5 or ½”” NPT-F