- Helukabel Việt Nam
- MICRO-EPSILON
- FrigorTec
- ZELTWANGER VIỆT NAM
- Clyde Việt Nam
- Electro-Chemical Devices (ECD)
- FER-strumenti Việt Nam
- Filternox Việt Nam
- D-Hydro
- FER Strumenti VIỆT NAM
- NUOVA FIMA VIETNAM
- Dover Flexo Electronics
- FTI Flow Technology
- OHKURA VIETNAM
- ASHCROFT VIỆT NAM
- DWYER VIỆT NAM
- BROOKS INSTRUMENT
- VEGA VIETNAM
- SCHENCK PROCESS VIETNAM
- FIREYE VIETNAM
- MOOG VIETNAM
- K0GANEI VIETNAM
- QUALITEST VIETNAM
- TECLOCK VIETNAM
- TEKTROL VIETNAM
- CELLAPORT PT VIETNAM
- WISE VIETNAM
- AT2E VIETNAM
- TEMA VIETNAM
- Taihei Boeki VIỆT NAM
- CEIA VIETNAM
- KNICK VIETNAM
- PRESSURE TECH VIỆT NAM
- ME-Meßsysteme VIỆT NAM
- TDK LAMBDA
- KLOEPPER-THERM VIỆT NAM
- BIRCHER VIETNAM
- IBA VIETNAM
- SORINC VIET NAM
- MONTECH VIET NAM
- BURKERT VIETNAM
- NIRECO VIETNAM
- CEMB VIETNAM
- MARK-10 VIETNAM
- GASTRON VIETNAM
- RED LION VIETNAM
- MATSUSHIMA VIETNAM
- TAKENAKA VIETNAM
- PORA VIETNAM
- GEMU VIETNAM
- BECKHOFF VIETNAM
Oxygen analyzers Mod. HT300 - FER-strumenti
-
CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT
Địa chỉ: Số 1, Đường số 27, phường Hiệp Bình Chánh, Quận Thủ Đức, Tp.HCM
Tell / zalo: 0977 204 306 / 0914 599 052
Email: sale18@tmpvietnam.com
Skype: duyvu181387@gmail.com
-
-
- Thông Tin Sản Phẩm
- Đánh Giá
Oxygen analyzers Mod. HT300 - FER-strumenti
Options
• Electronic device for the electrodes regeneration.
• Membrane pump and flowmeters housed inside the electronic enclosure (see picture on the right);
• Inox AISI 316 IP 66 enclosures;
• Pressure reducer for the supply of air from the instrument air net (instead of the pump);
• Mounting flanges and extra tubes, ceramic and metallic for protection of the probe;
• 2x1.5 connection cables and 6x4 mm tubing.
Technical Specifications
• Measuring range: 0,0001 ÷ 25% O2 volume
• Accuracy: in the range of %: ± 0.5% of theoretical value or 0,5% di O2
(whichever is the greater) In the range of ppm: 0.5% of full range
• Stability: within 1%
• Response time: (90%): cell < 1", system < 15"
• Storage temperature: -40°C/+80°C
• Temperature limits: probe: 500°÷1600°C for the part in the process, < 150 C º for the head of the probe. Converter and flow-meter box -20÷ +45º C; R.H. < 90 non condensation
• Analogue output: 4 ÷ 20 mA 500 ohm or 0 – 10 V 10 mA linear on one of the following fields: 0 ÷ 1999 ppm; 0 ÷ 5%; 0 ÷ 10%; 0 ÷ 21%; 0 ÷ 25%
• Serial interfaces: RS232 and Mod-Bus RTU on RS 485. Hart protocol version 6.0 for H 095 model.
• Potential free alarm contacts (only for H705 and Pro-Oxy) for high & low O2
, instrument fault (fail safe), service (fail safe). For all: 250 V, 1 A max
• In case of fault the analogue output is forced to 2 mA or 0 V (only for H705 and Pro-Oxy)
• Dumper: time constant settable between 0 e 900 seconds
• Power: 115V - 230V ± 10%, 50/60 Hz, 50 Va max. For H095 24 V DC
• EMC according to EN 50081 and EN 50082
• Electrical safety: according to EN 61010 – 1, UL 61010-1
• Protection: Probe IP 66. Converter and flow-meter box IP 65.
• Electric connection probe/electronic unit: copper shielded cable 2x1.5 max length mt 100
• Pneumatic connection probe/flowmeter box: rigid or flexible tubing mm.6x4
• Probe dimension: part in the process= 900, 650, 500, 310 mm. Diameter = 28 mm. Using suitable extension tubes, the maximum immersion length of 1500 mm can be reached. Transmitter (H705) = mm.300x400x150, weight approx. kg 11. Flow-meter box mm. 230x300x170, weight approx. kg.7.
• EAC Conformity Declaration according to TR-CU-004 e TR-CU-020 directives.