- Helukabel Việt Nam
- MICRO-EPSILON
- FrigorTec
- ZELTWANGER VIỆT NAM
- Clyde Việt Nam
- Electro-Chemical Devices (ECD)
- FER-strumenti Việt Nam
- Filternox Việt Nam
- D-Hydro
- FER Strumenti VIỆT NAM
- NUOVA FIMA VIETNAM
- Dover Flexo Electronics
- FTI Flow Technology
- OHKURA VIETNAM
- ASHCROFT VIỆT NAM
- DWYER VIỆT NAM
- BROOKS INSTRUMENT
- VEGA VIETNAM
- SCHENCK PROCESS VIETNAM
- FIREYE VIETNAM
- MOOG VIETNAM
- K0GANEI VIETNAM
- QUALITEST VIETNAM
- TECLOCK VIETNAM
- TEKTROL VIETNAM
- CELLAPORT PT VIETNAM
- WISE VIETNAM
- AT2E VIETNAM
- TEMA VIETNAM
- Taihei Boeki VIỆT NAM
- CEIA VIETNAM
- KNICK VIETNAM
- PRESSURE TECH VIỆT NAM
- ME-Meßsysteme VIỆT NAM
- TDK LAMBDA
- KLOEPPER-THERM VIỆT NAM
- BIRCHER VIETNAM
- IBA VIETNAM
- SORINC VIET NAM
- MONTECH VIET NAM
- BURKERT VIETNAM
- NIRECO VIETNAM
- CEMB VIETNAM
- MARK-10 VIETNAM
- GASTRON VIETNAM
- RED LION VIETNAM
- MATSUSHIMA VIETNAM
- TAKENAKA VIETNAM
- PORA VIETNAM
- GEMU VIETNAM
- BECKHOFF VIETNAM
MÁY QUÉT NGỌN LỬA INSIGHT SERIES 4
- THÀNH PHẦN :Bộ giám sát ngọn lửaCông Ty Tăng Minh Phát chuyên cung cấp thiết bị của hãng Fireye tại Việt Nam, bộ điều khiển ngọn lửa, bộ giám sát ngọn lửa, thiết bị kiểm soát ngọn lửa, Fireye Vietnam
-
- Thông Tin Sản Phẩm
- Đánh Giá
Máy quét ngọn lửa InSight Series 4
The InSight Series 4 scanner has numerous adjustment options available. It can be tuned either automatically or manually to achieve the optimum level of sensitivity to the target flame balanced with superior discrimination of background radiation.
The InSight Series 4 scanner measures the amplitude of the modulations (the flame “flicker”) that occur within the targeted flame. The sensor within the scanner measures these amplitudes seen within either the ultraviolet (UV) or infrared (IR) spectral ranges across a wide range of flicker frequency bands. In addition the scanner has a flame relay (FR) that can be related to the sensor signals in logical configurations.
During the scanner set up procedure, the logical operation for the flame relay is selected based on the settings relative to user gain, required (flicker) frequency band and switching thresholds. Refer to commissioning procedure for more details on set up procedures)is selected for the desired sensor.
The current Flame Signal Strength (FS) can be viewed on the scanner display via the main menu. This displayed value is the measure of amplitude within the selected modulation (flicker) frequency band, for example: FS=185 (Flame signal for sensors ranges from 0 to 999)
Features | 95UVS4- | 95IRS4- | 95UVS4E- | 95IRS4E- | 95UVS4-1 | 95IRS4-1 | 95UVS4-1CEX | 95IRS4-1CEX |
1WINC | 1WINC | 1WINC | 1WINC | 95UVS4-2 | 95IRS4-2 | 95UVS4-2CEX | 95IRS4-2CEX | |
UV or IR Sensor | UV | IR | UV | IR | UV | IR | UV | IR |
Flame Relay | YES | YES | YES | YES | YES | YES | YES | YES |
Fault Relay | YES | YES | YES | YES | YES | YES | YES | YES |
4-20 mA Output | YES | YES | YES | YES | YES | YES | YES | YES |
Modulation Frequency Selectors | 21 | 21 | 21 | 21 | 21 | 21 | 21 | 21 |
Memory Files | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
Communications | YES | YES | YES | YES | YES | YES | YES | YES |
Auto Config | YES | YES | YES | YES | YES | YES | YES | YES |
2 X 16 Alpha Display | YES | YES | YES | YES | YES | YES | YES | YES |
Housing Material | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum |
THÔNG SỐ KỸ THUẬT:
Housing Material: Standard Models and CEX: Cast aluminum with gray polyester powder coat finish Ingress Protection IP66 with 0.4 joule impact rating |
Housing Weight: Standard Models: 5.9 lbs. (2.69kg); CEX Model: 13.2 lbs (5.98 kg)
|
Mounting: Requires one threaded mounting flange, ordered separately (see below).
|
For fiber optic mount, refer to bulletin CU-117. In the specific case of installation on InSight I fiber optics already in place refer to bulletin 133-754 and use Adapter Kit 129-193.
|
Cooling / Purge Air Requirements: Source: Clean, dry, cool
|
Volume: 4 SCFM (113 l/min) at 3/8” threaded mounting flange, or 1 inch “Y” fitting, mounted on scanner sight pipe. Temperature near the upper limit of the scanner operating range and/or use with dirty/dusty fuels may require up to 15 SCFM (425 l/min). |
Pressure: Adequate to overcome furnace or windbox pressure
|
Operating Temperature Rating: -40°F to + 150°F Ta (-40°C to +65°C Ta)
|
Storage Temperature Rating: -40°F to + 185°F Ta (-40°C to +85°C Ta) Humidity: 0% to 95% relative humidity, non-condensing
|
STANDARD MOUNTING FLANGE:
|
Material/Weight: Cast aluminum with gray polyester powder coat finish. Contains an integral heat-insulating female thread insert 3 lb (1.4 kg)
|
Flange Threads: P/N 60-2919-1 1" NPT female pipe mount with 3/8” NPT female cooling air connection. P/N 60-2919-2 1" BSP female pipe mount with 3/8” BSP female cooling air connection. |
OPTIONAL MOUNTING FLANGE, CAST ALUMINUM:
|
Material/Weight: Cast aluminum (without heat-insulating thread insert), with grey polyester powder coat finish / 0.5 lbs (0.23 kg)
|
Flange Threads: P/N 60-2692, 1" NPT female pipe mount with 3/8" NPT female cooling air connection. P/N 60-2693, 1" BSP female pipe mount with 3/8" BSP female cooling air connection. |
ELECTRICAL:
|
Input Power: 24 Vdc, +10%, -15% supply current: 0.25A, 6VA, Hold Time must be 20 msec Min. Fireye power supply 60-2685 is recommended
|
Electrical Connection: 12-pin screw type quick-disconnect
|
Relay Output: FLAME RELAY, SPST (N.O.)
|
FAULT RELAY, SPST (N.C.)
|
Contact Rating: Minimum: 10 mA @ 5 Vdc (All models)
|
Maximum: 2 A @ 30 Vdc; 2A @ 50 Vac (Series 4E-1WINC models only) Maximum 2A @ 30 Vdc; 2A @ 230 VAC (All other models)
|
Analog Output: 4-20 mA dc current, referenced to 24Vdc common, Max. connected 1oad: 750 ohms
|
Operator Interface: Alpha -Numeric Display with five pushbutton keys.
|
Cable Specification: P/N 59-547 (12-conductor):
|
Multi-core, 12 conductor (color coded), 18- AWG, with foil wrap and overall braided shield and drain wire. PLTC-ER rating. Maximum cable length 1000 feet (305 meters) Cable Jacket: PVC / black (flame-retardant, RoHS compliant)
|
Temperature Rating: -40°F to +221°F (-40°C to +105°C)
|
P/N 59-547 Nominal O.D. 0.52" (13.2 mm), maximum O.D. 0.56” (14.2mm)
|
Vibration specs: Frequency range: 10 Hz – 150 Hz.
|
Acceleration / Amplitude: 58 to 150 Hz: 1.0 g / 10 to 58 Hz: 0.075 , Sweep rate: 1 octave per minute Number of sweep cycles: 10 Number of axes: 3, mutually perpendicular |